{"id":37310,"date":"2026-09-07T16:34:40","date_gmt":"2026-09-07T08:34:40","guid":{"rendered":"https:\/\/www.shiyifiltration.com\/?p=37310"},"modified":"2026-09-07T17:09:16","modified_gmt":"2026-09-07T09:09:16","slug":"cement-plant-main-reducer-of-cement-mill","status":"publish","type":"post","link":"https:\/\/www.shiyifiltration.com\/index.php\/2026\/09\/07\/cement-plant-main-reducer-of-cement-mill\/","title":{"rendered":"Cement plant Main reducer of cement mill"},"content":{"rendered":"\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"569\" height=\"329\" src=\"https:\/\/www.shiyifiltration.com\/wp-content\/uploads\/2026\/09\/image-22.png\" alt=\"\" class=\"wp-image-37311\" srcset=\"https:\/\/www.shiyifiltration.com\/wp-content\/uploads\/2026\/09\/image-22.png 569w, https:\/\/www.shiyifiltration.com\/wp-content\/uploads\/2026\/09\/image-22-149x86.png 149w, https:\/\/www.shiyifiltration.com\/wp-content\/uploads\/2026\/09\/image-22-400x231.png 400w, https:\/\/www.shiyifiltration.com\/wp-content\/uploads\/2026\/09\/image-22-429x248.png 429w\" sizes=\"(max-width: 569px) 100vw, 569px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-wd-title title wd-9f6e7559\">Customer Application Research Report<br>Customer<br>A large listed cement group, a century-old enterprise<br>System Introduction<br>Main reduction gearbox of Cement Mill #1 has a light-oil lubrication station with an oil capacity of 8000L<br>Oil Information: Mobil 600XP 320 gear oil.<br>The oil station is located 3 meters underground.<\/h2>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-wd-title title wd-fd837864\">Problem<br>The cooling tower unexpectedly leaked, causing a large amount of water to enter the gearbox oil reservoir. The customer discharged 250kg of water using natural separation and sedimentation, but believes that there is still 750kg of water left in the tank. On-site, the customer has a vacuum dehydration device and tried to use vacuum to remove water from the gear oil. However, they found that the temperature inside the vacuum chamber had already reached 100\u00b0C, but no water was coming out of the vacuum device's drain.<\/h2>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"577\" height=\"423\" src=\"https:\/\/www.shiyifiltration.com\/wp-content\/uploads\/2026\/09\/image-23.png\" alt=\"\" class=\"wp-image-37312\" srcset=\"https:\/\/www.shiyifiltration.com\/wp-content\/uploads\/2026\/09\/image-23.png 577w, https:\/\/www.shiyifiltration.com\/wp-content\/uploads\/2026\/09\/image-23-149x109.png 149w, https:\/\/www.shiyifiltration.com\/wp-content\/uploads\/2026\/09\/image-23-400x293.png 400w, https:\/\/www.shiyifiltration.com\/wp-content\/uploads\/2026\/09\/image-23-430x315.png 430w\" sizes=\"(max-width: 577px) 100vw, 577px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-wd-title title wd-5fdee322\">Customer request:<br>Online dehydration, quickly remove free water and emulsified water from the oil station without stopping production. The gear oil has already heavily emulsified and turned milky white. The 750kg of water is the customer's estimate.<\/h2>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-10f18701\">Solution: Install Shiyi @ Extraction Tower C51<\/h2>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-wd-title title wd-58ba4e07\">Comparison of gear oil before and after dehydration. During dehydration, the client adds oil to the tank due to the drop in liquid level.<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"565\" height=\"309\" src=\"https:\/\/www.shiyifiltration.com\/wp-content\/uploads\/2026\/09\/image-24.png\" alt=\"\" class=\"wp-image-37313\" srcset=\"https:\/\/www.shiyifiltration.com\/wp-content\/uploads\/2026\/09\/image-24.png 565w, https:\/\/www.shiyifiltration.com\/wp-content\/uploads\/2026\/09\/image-24-150x82.png 150w, https:\/\/www.shiyifiltration.com\/wp-content\/uploads\/2026\/09\/image-24-400x219.png 400w, https:\/\/www.shiyifiltration.com\/wp-content\/uploads\/2026\/09\/image-24-430x235.png 430w\" sizes=\"(max-width: 565px) 100vw, 565px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-wd-title title wd-2c389d60\">Customer Review: Initially, the customer was skeptical about whether the Shiyi @ Extraction Tower C51 could dehydrate online. As we all know, dehydrating high-viscosity gear oil is very challenging. The customer had to choose between filtration dehydration service and oil change. Undoubtedly, the C51 fully met the customer's requirements, saving them 800 liters worth of oil change costs, and production was not affected at all.<\/h2>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-wd-title title wd-4be39eed\">Online dehydration, add the oil to the tank after dehydration is complete<\/h2>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"344\" height=\"398\" src=\"https:\/\/www.shiyifiltration.com\/wp-content\/uploads\/2026\/09\/image-25.png\" alt=\"\" class=\"wp-image-37314\" srcset=\"https:\/\/www.shiyifiltration.com\/wp-content\/uploads\/2026\/09\/image-25.png 344w, https:\/\/www.shiyifiltration.com\/wp-content\/uploads\/2026\/09\/image-25-150x173.png 150w, https:\/\/www.shiyifiltration.com\/wp-content\/uploads\/2026\/09\/image-25-259x300.png 259w\" sizes=\"(max-width: 344px) 100vw, 344px\" \/><\/figure>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-wd-title title wd-daed737e\">After dehydration is completed, record the amount of oil added and the amount of water removed. Out of 8000L of oil, 2000L of water was removed, which means the oil still contained as much as 25% water. The actual water content is much higher than the customer's estimated 750kg.<\/h2>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":37332,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":""},"categories":[199],"tags":[],"class_list":["post-37310","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-dehydration-cement-plant"],"_links":{"self":[{"href":"https:\/\/www.shiyifiltration.com\/index.php\/wp-json\/wp\/v2\/posts\/37310","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.shiyifiltration.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.shiyifiltration.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.shiyifiltration.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.shiyifiltration.com\/index.php\/wp-json\/wp\/v2\/comments?post=37310"}],"version-history":[{"count":0,"href":"https:\/\/www.shiyifiltration.com\/index.php\/wp-json\/wp\/v2\/posts\/37310\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.shiyifiltration.com\/index.php\/wp-json\/wp\/v2\/media\/37332"}],"wp:attachment":[{"href":"https:\/\/www.shiyifiltration.com\/index.php\/wp-json\/wp\/v2\/media?parent=37310"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.shiyifiltration.com\/index.php\/wp-json\/wp\/v2\/categories?post=37310"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.shiyifiltration.com\/index.php\/wp-json\/wp\/v2\/tags?post=37310"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}